Study of the Improvement of False Fire Alarms in Analog Photoelectric Type Smoke Detectors
Seo Byung Keun, Nam Sang Gu
Fire Sci. Eng.. 2016;30(5):108-115.   Published online 2016 Oct 31     DOI: https://doi.org/10.7731/KIFSE.2016.30.5.108
Citations to this article as recorded by Crossref logo
Analysis of Non-fire Alarm Causes using Malfunction Cases by Automatic Fire Detection Equipment Type in Large Shipyards
Sun-Woo Kim, Ryun-Seok Oh, Young-Hoon Bae, Jun-Ho Choi
Fire Science and Engineering.2023; 37(1): 51.     CrossRef
Study on the Application of Carbon Monoxide Sensors for the Prevention of Unwanted Alarms
Su-Gil Choi, Yoo-Jeong Choi, Si-Kuk Kim
Fire Science and Engineering.2023; 37(1): 57.     CrossRef
Multiple-Scattering-Based Optical Simulation for Analyzing Response Characteristics of Photoelectric Smoke Detectors
Soocheol Kim, Hoesung Yang, Kyuwon Han, Yusun Ahn, Sang Gi Hong, Kangbok Lee
Fire Science and Engineering.2023; 37(6): 48.     CrossRef
Flame Segmentation Characteristics of YCbCr Color Model Using Object Detection Technique
Joo-Hyung Roh, Se-Hong Min, Min-suk Kong
Fire Science and Engineering.2023; 37(6): 54.     CrossRef
Development of a Photoelectric Smoke Detector with a Built-in Function to Prevent False Alarms Owing to Humidity
Sikuk Kim
International Journal of Fire Science and Engineering.2023; 37(4): 9.     CrossRef
Study on the Smoke and CO Alarm Concentrations to Develop a Smoke & CO Combination Detector
Sikuk Kim
International Journal of Fire Science and Engineering.2023; 37(4): 43.     CrossRef
Experimental Research on Operation Characteristics of Smoke Detection Equipment with respect to Varying Humidity Environments
Su-Gil Choi, Yoo-Jeong Choi, Si-Kuk Kim
Fire Science and Engineering.2022; 36(1): 23.     CrossRef
Fire Image Classification Based on Convolutional Neural Network for Smart Fire Detection
Joohyung Roh, Yukyung Kim, Minsuk Kong
International Journal of Fire Science and Engineering.2022; 36(3): 51.     CrossRef
Sinusoidal Current Signal-Based Fire Detection System with Automatic Address Assignment
Man Hee Lee, Seog Chae, Soo Young Shin
Electronics.2022; 11(19): 3131.     CrossRef
The Development of Symbolic Expressions for Fire Detection with Symbolic Classifier Using Sensor Fusion Data
Nikola Anđelić, Sandi Baressi Šegota, Ivan Lorencin, Zlatan Car
Sensors.2022; 23(1): 169.     CrossRef
Analysis of Fire Prediction Performance of Image Classification Models based on Convolutional Neural Network
Joo-Hyung Roh, Se-Hong Min, Min-Suk Kong
Fire Science and Engineering.2022; 36(6): 70.     CrossRef
A Study on the Response Characteristics of Fire Detector and Indoor Air Quality Measurement Factor According to UL 268 Cooking Nuisance Test
Yoo-Jeong Choi, Su-Gil Choi, Yeong-Jae Nam, Jae-Hyeon Yu, Euy-Hong Hwang, Sung-Eun Lee, Si-Kuk Kim
Fire Science and Engineering.2021; 35(1): 67.     CrossRef
Statistics and Management Systems of Unwanted Domestic and Foreign Fire Alarms
Euy-Hong Hwang, Sung-Eun Lee, Don-Mook Choi
Fire Science and Engineering.2020; 34(2): 30.     CrossRef