Fire Sci. Eng. Search

CLOSE


Fire Sci. Eng. > Volume 32(6); 2018 > Article
Fire Science and Engineering 2018;32(6):34-39.
DOI: https://doi.org/10.7731/KIFSE.2018.32.6.034    Published online December 31, 2018.
음파 소화기를 이용한 안전 스토브 시스템 개발
서윤원, 이석재, 박형주, 김기남, 최용래, 황형준, 한승한, 심동하
1서울과학기술대학교 MSDE전공
2서울과학기술대학교 MSDE전공
3서울과학기술대학교 MSDE전공
4서울과학기술대학교 MSDE전공
5서울과학기술대학교 MSDE전공
6서울과학기술대학교 MSDE전공
7서울과학기술대학교 스마트생산융합시스템공학과
8서울과학기술대학교 MSDE전공
Development of Safe Stove System using Sound Wave Fire Extinguisher
Seo Yunwon, Lee Sukjae, Park yungjoo, Kim Kinam, Choi Yongrae, Hwang Hyungjun, Han Seunghan, Shim Dongha
1MSDE Programme, SeoulTech
2MSDE Programme, SeoulTech
3MSDE Programme, SeoulTech
4MSDE Programme, SeoulTech
5MSDE Programme, SeoulTech
6MSDE Programme, SeoulTech
7Dept. of MSDE, SeoulTech
8MSDE Programme, SeoulTech
요약
본 논문에서는 최초로 음파 소화기를 이용한 자동 화재진압 기능을 가진 안전 스토브 아키텍처를 제안하고 개발하였다. 화재가 발생하면 화재 센서와 연동된 마이크로컨트롤러가 화재를 감지하고 음파 소화기를 구동하여 화재를 진압하는 구조를 가진다. 음파 소화기는 스피커와 콜리메이터로 구성되며, 오디오 증폭기를 포함하는 구동모듈에 의해 구동된다. 스토브를 둘러싸는 인클로저를 사용해 거리에 따른 음파의 확산을 막아 음파의 감쇠를 줄일 수 있었다. 이때, 사용된 음파의 주파수는 50 Hz이며, 음압은 소화기로 부터 0.5 m 거리에서 93 dBA로 측정되었다. 7 cc 및 14 cc의 가연성 액체에서 발생한 화염에 대해 진화에 소요되는 시간은 각각 최대 8 s와 15 s로, 각각 자연소화 시간의 24%와 42%에 해당한다. 제안된 안전 스토브는 기존 안전 스토브와 비교하여 무해하고 잔여물질이 남지 않기 때문에, 다양한 가전기기에 적용되어 원활한 초기 화재 진압 및 화재 확산 방지에 기여할 것으로 기대된다.
Abstract
In this paper, the architecture of a safe stove with an automatic fire suppression function using a sound wave fire extinguisher has been proposed and developed for the first time. A microcontroller connected to a fire sensor detects and suppresses a fire by driving a fire extinguisher. The sound wave fire extinguisher is composed of a speaker and collimator, and is driven by a driver module including an audio amplifier. The attenuation of the sound wave is reduced by preventing the sound diffusion with an enclosure surrounding a stove. The frequency of the sound wave is set to 50 Hz, and the sound pressure of 93 dBA is measured at the distance of 0.5 m. It takes maximum 8 and 15 seconds to suppress the flame from 7-cc and 14-cc flammable liquid, respectively, which corresponds to 24% and 42% of the natural extinguishing time. Since the proposed safe stove is non-toxic and leaves no residues over the conventional ones, it would combine with various home appliances to suppress early-stage fires and prevent fire expansion.
Key Words: Safe stove, Sound fire extinguisher, Fire sensor, Microcontroller


ABOUT
BROWSE ARTICLES
EDITORIAL POLICY
AUTHOR INFORMATION
Editorial Office
Room 906, The Korea Science Technology Center The first building, 22, Teheran-ro 7 Gil, Gangnam-gu, Seoul, Republic of Korea
Tel: +82-2-555-2450/+82-2-555-2452    Fax: +82-2-3453-5855    E-mail: kifse@hanmail.net                

Copyright © 2024 by Korean Institute of Fire Science and Engineering.

Developed in M2PI

Close layer
prev next