2. NFSC 501. “National Fire Safety Code for Smoke Control System”, (2017).
3. Q Tan and Y Jaluria, ““Mass Flow through a Horizontal Vent in an Enclosure due to Pressure and Density Differences””, International Journal of Heat and Mass Transfer, Vol. 44, No. 8, pp. 1543-1553 (2001),
https://doi.org/10.1016/S0017-9310(00)00198-8.
4. W. K Chow and Y Gao, ““Buoyancy and Inertial Force on Oscillations of Thermal-induced Convective Flow across a Vent””, Building and Environment, Vol. 46, No. 2, pp. 315-323 (2011),
https://doi.org/10.1016/j.buildenv.2010.07.023.
5. X Chen, ““Invesigation of Horizontal Vent Flow Behavior Coupling with Fire Behavior in a Ceiling Vented Enclosure””, Ph.D. Thesis, Hong Kong University (2015).
6. L. Y Cooper, ““Combined Buoyancy and Pressure-driven Flow through a Shallow, Horizontal, Circular Vent””, Journal of Heat Transfer, Vol. 117, No. 3, pp. 659-667 (1995),
https://doi.org/10.1115/1.2822627.
7. M Epstein, ““Buoyancy-driven Exchange Flow through Small Openings in Horizontal Partitions””, Journal of Heat Transfer, Vol. 110, No. 4a, pp. 885-893 (1988),
https://doi.org/10.1115/1.3250589.
10. S. A Baek, ““An Experimental Investigation on Effects of Fire Source and Opening Conditions on Temperature Distribution and Flow through Opening in Enclosure””, Master's Thesis, Pukyong National University (2020).
11. Public Performance Act, §, Vol. 12, No. 7, (2015).
12. B Karlsson and J Quintiere, ““Enclosure Fire Dynamics””, CRC Press (1999).
13. K McGrattan, S Hostikka, R McDermott, J Floyd, C Weinschenk and K Overholt, ““Fire Dynamics Simulator Technical Reference Guide Volume 3:Validation””, NIST Special Publication 1018-3, Sixth Edition, pp. 70-74 (2017).
14. K McGrattan, S Hostikka, R McDermott, J Floyd, C Weinschenk and K Overholt, ““Fire Dynamics Simulator User's Guide””, NIST Special Publication, 1019, Sixth Edition, pp. 37(2013).
15. D Stroup and A Lindeman, ““Verification and Validation of Selected Fire Models for Nuclear Power Plant Applications””, NUREG-1824, Supplement 1, United States Nuclear Regulatory Commission, EPRI 1011999, Washington, DC (2013).
16. J. H Yang, S. A Baek, C. Y Lee and D Kim, ““Examination on Numerical Simulation Using Reduced-scale Model of Theater Fire:Influences of Fire Curtain and Stage Natural Vent””, Fire Science and Engineering, Vol. 33, No. 5, pp. 37-47 (2019),
https://doi.org/10.7731/KIFSE.2019.33.5.037.
17. S. A Baek, J. H Yang, C. S Jeong, C. Y Lee and D Kim, ““Reduced-scale Model Experiment for Examination of Natural Vent and Fire Curtain Effects in Fire of Theater Stage””, Fire Science and Engineering, Vol. 33, No. 4, pp. 41-49 (2019),
https://doi.org/10.7731/KIFSE.2019.33.4.041.