J. Kor. Inst. Fire Sci. Eng. Search

CLOSE


Fire Sci. Eng. > Volume 26(4); 2012 > Article
Journal of Korean Institute of Fire Science and Engineering 2012;26(4):55-62.
DOI: https://doi.org/10.7731/KIFSE.2012.26.4.055    Published online August 31, 2012.
국소방출방식 개념의 대향류 확산화염에서 CO2 소화효과에 관한 수치해석 연구
문선여, 박충화, 황철홍, 오창보
1대전대학교 소방방재학과
2대전대학교 소방방재학과
3대전대학교 소방방재학과
4부경대학교 안전공학과
A Numerical Study on the Extinguishing Effects of CO2 in Counterflow Diffusion Flames with the Concept of Local Application System
Mun Sun-Yeo, Park Chung-Hwa, Hwang Cheol-Hong, Oh Chang-Bo
1Dept. of Fire & Disaster Prevention, Daejeon University
2Dept. of Fire & Disaster Prevention, Daejeon University
3Dept. of Fire & Disaster Prevention, Daejeon University
4Dept. of Safety Engineering, Pukyong National University
요약
소화약제의 국소방출방식 개념이 적용될 수 있는 대향류 확산화염을 대상으로 $CO_2$ 소화약제의 소화기구를 재조명하기 위한 연구가 시도되었다. 이를 위해 연료 또는 공기류에 $CO_2$가 첨가된 낮은 총괄신장율의 $CH_4$/air 대향류 확산화염이 상세반응을 이용한 수치해석을 통해 검토되었다. 첨가된 $CO_2$를 포함한 복사 참여 화학종의 복사 열손실을 고려하기 위하여 optically thin model(OTM)이 적용되었다. 주요 결과로서, 공기류에 첨가된 $CO_2$의 소화농도 예측결과는 문헌에 보고된 실험결과를 적절하게 예측하고 있으나, 연료류에 첨가된 경우 다소 과소 예측된 결과를 확인하였다. 소화효과에 대한 정량적 분석을 위하여 가상의 소화약제의 개념이 도입되었다. $CO_2$ 소화효과의 분석을 통해 총괄신장율($a_g$)에 따른 순수 희석효과, 복사 열손실 및 열용량에 의한 열적효과 그리고 $CO_2$의 연쇄반응 억제를 통한 화학적 효과의 정량적 기여도를 구체적으로 확인할 수 있었다.
Abstract
The suppression mechanisms of carbon dioxide ($CO_2$) as a representative fire suppression agent were revisited using a counterflow diffusion flame which could be applied the concept of a local application system. To end this, the low strain rate $CH_4$/air counterflow diffusions with $CO_2$ addition in either fuel or oxidizer stream were examined numerically using detailed-kinetic chemistry. Radiative heat loss due to radiating gas species including $CO_2$ added was considered by the optically thin model (OTM). As a result, the critical $CO_2$ volume fractions in the oxidizer stream required to extinguish the flame were in good agreement with the experimental data reported in the literature, while somewhat under-prediction was observed with $CO_2$ added in the fuel stream. The surrogate agents were adopted to estimate the quantitative contribution with changing in global strain rate ($a_g$) on the flame extinguishment among pure dilution effect, thermal effects including radiation heat loss and chemical effect due to the $CO_2$ fire suppression agent.
Key Words: $CO_2$ fire suppression agent, Local application system, Counterflow diffusion flame


ABOUT
BROWSE ARTICLES
EDITORIAL POLICY
AUTHOR INFORMATION
Editorial Office
Room 906, The Korea Science Technology Center The first building, 22, Teheran-ro 7 Gil, Gangnam-gu, Seoul, Republic of Korea
Tel: +82-2-555-2450/+82-2-555-2452    Fax: +82-2-3453-5855    E-mail: kifse@hanmail.net                

Copyright © 2024 by Korean Institute of Fire Science and Engineering.

Developed in M2PI

Close layer
prev next