CrossRef Text and Data Mining
Result of CrossRef Text and Data Mining Search is the related articles with entitled article. If you click link1 or link2 you will be able to reach the full text site of selected articles; however, some links do not show the full text immediately at now. If you click CrossRef Text and Data Mining Download icon, you will be able to get whole list of articles from literature included in CrossRef Text and Data Mining.
Effect of Radiation Models on the Suppression Limits in Counterflow Methane/Air Diffusion Flames
Mun Sun-Yeo, Cho Jae-Ho, Hwang Cheol-Hong, Oh Chang Bo, Park Won-Hee
Fire Sci. Eng.. 2014;28(3):20-28.   Published online June 30, 2014
DOI: https://doi.org/10.7731/KIFSE.2014.28.3.020

Excel Download

A Study of the Effects of Air-Preheat on the Structure of Methane-Air Counterflow Diffusion Flames
Heat Transfer: Volume 2 — Combustion and Radiation Heat Transfer. 1998;   Crossref logo
Link1 Link2

Structure and sooting limits in counterflow methane/air and propane/air diffusion flames from 1 to 5 atmospheres
Symposium (International) on Combustion. 1998;27(1):1523-1529   Crossref logo
Link1 Link2

97/03069 Radiation extinction limit of counterflow premixed lean methane-air flames
Fuel and Energy Abstracts. 1997;38(4):252   Crossref logo
Link1 Link2

Extinction and structure of methane/very lean methane-air counterflow diffusion flames
Symposium (International) on Combustion. 1988;21(1):1837-1843   Crossref logo
Link1 Link2

00/02778 A study of the effects of air preheat on the structure of methane/air counterflow diffusion flames
Fuel and Energy Abstracts. 2000;41(5):308   Crossref logo
Link1 Link2

Laser-induced fluorescence measurements and modeling of nitric oxide in methane–air and ethane–air counterflow diffusion flames
Combustion and Flame. 2000;120(3):372-382   Crossref logo
Link1 Link2

A study of the effects of air preheat on the structure of methane/air counterflow diffusion flames
Combustion and Flame. 2000;121(1-2):262-274   Crossref logo
Link1 Link2

A numerical study of counterflow diffusion flames of methane/air at various pressures
Science China Technological Sciences. 2014;57(3):615-624   Crossref logo
Link1 Link2 Link3

Structure and extinction limits of counterflow diffusion flames of hydrogen-nitrogen mixtures in air
Symposium (International) on Combustion. 1989;22(1):1461-1470   Crossref logo
Link1 Link2

Radiation extinction limit of counterflow premixed lean methane-air flames
Combustion and Flame. 1997;109(4):639-646   Crossref logo
Link1 Link2