Fire Sci. Eng. Search

CLOSE


Fire Sci. Eng. > Volume 32(6); 2018 > Article
Fire Science and Engineering 2018;32(6):74-83.
DOI: https://doi.org/10.7731/KIFSE.2018.32.6.074    Published online December 31, 2018.
산불진화대원용 안전장갑에 대한 성능평가 기준 연구
김해형, 이선영, 정재한, 권춘근, 안희영, 홍승태
1한국소방산업기술원 기술관리부
2한국소방산업기술원 소방기술연구소
3한국소방산업기술원 소방기술연구소
4국립산림과학원 산림방재연구과
5국립산림과학원 산림방재연구과
6한국소방산업기술원 소방기술연구소
A Study on Performance Evaluation Criteria for Safty Gloves for Forest Firefighting Crews
Kim Hae-Hyoung, Lee Seon-Yeong, Jeong Jae-Han, Kwon ChunGeun, Ahn Heeyoung, Hong Seung-Tae
1Technology Management Department, Korea Fire Institute
2R&D Lab. Korea Fire Institute
3R&D Lab. Korea Fire Institute
4Dept. of Forest Conservation, National Institute of Forest Science
5Dept. of Forest Conservation, National Institute of Forest Science
6R&D Lab. Korea Fire Institute
요약
산불진화대원의 안전 확보와 작업능률 향상을 위해 안전장갑에 대한 성능평가 기준을 개발하였다. 산불진화대원용 안전장갑에 대한 기준이 현재 국내에 없기 때문에 한국소방산업기술원(KFI)에서 운용중인 소방대원용 안전장갑에 대한 기준을 기초로 하여 연구를 시작하였다. 관계자 의견 수렴 및 외국 기준의 검토를 통하여 17개 시험항목 중 5개 시험항목을 제외하고 12개 시험항목을 선정하였다. 시료는 산불진화대원들이 사용하고 있는 2 종류의 일반 안전장갑과 하나의 소방대원용 장갑에 대해 KFI 기준을 적용하여 시험하고 그 결과를 비교하였다. 시험 결과 불에 약한 나일론이나 폴리우레탄 등의 재질은 산불진화대원용 안전장갑에 적합하지 않음을 확인하였다. KFI 기준과 ISO 16073, NFPA 1977, NFPA 1971 및 BS EN 659의 판정기준을 비교하여 우리나라 산불진화대원들의 작업 환경에 적합한 12개 시험항목과 판정기준들을 최종 선정하였다.
Abstract
In order to secure safety and improve work efficiency of forest firefighting crews, performance evaluation criteria for safety gloves were developed. Since the standard for forest firefighting safety gloves is not available in Korea, we started the study based on the standard for firefighting safety gloves operated by KFI. 12 test items were selected excluding 5 test items out of the 17 test items through the consultation of stakeholders and the review of foreign standards. Two types of general safety gloves used by forest firefighting crews and one firefighting gloves were tested by applying KFI standard and the results were compared. Materials such as nylon or polyurethane which are weak to fire are not suitable for forest firefighting safety gloves. We compared the criteria of KFI, ISO 16073, NFPA 1977, NFPA 1971 and BS EN 659, and finally selected 12 test items and acceptance criteria suitable for the work environment of forest firefighting crews in Korea.
Key Words: Safety gloves, Performance evaluation criteria, Forest firefighting crews


ABOUT
BROWSE ARTICLES
EDITORIAL POLICY
AUTHOR INFORMATION
Editorial Office
Room 906, The Korea Science Technology Center The first building, 22, Teheran-ro 7 Gil, Gangnam-gu, Seoul, Republic of Korea
Tel: +82-2-555-2450    Fax: +82-2-3453-5855    E-mail: kifse@hanmail.net                

Copyright © 2022 by Korean Institute of Fire Science and Engineering.

Developed in M2PI

Close layer
prev next