1. J. G Quintiere, “Principles of Fire Behavior, 2nd Ed.” CRC Press, Boca Raton, FL, (2017).
2. A Collin, S Lechene, P Boulet and G Parent, “Water Mist and Radiation Interactions:Application to a Water Curtain Used as a Radiative Shield”, Numerical Heat Transfer, Part A, Vol. 57, pp. 537-553 (2010),
https://doi.org/10.1080/10407781003744722.
3. S. C Lee, B. J Kim, J. O Lee, C. H Park and C. H Hwang, “An Experimental Study on the Effects of the Shape of a Drencher Head on the Characteristics of a Water Curtain”, Fire Science and Engineering, Vol. 30, No. 3, pp. 86-93 (2016),
https://doi.org/10.7731/KIFSE.2016.30.3.086.
4. K. J Kim, D. W Song and S. K Lee, “A Study on Performance of Water Curtain Nozzles for Protection of Wooden Cultural Properties from Forest Fire”, Fire Science and Engineering, Vol. 26, No. 3, pp. 8-13 (2012),
https://doi.org/10.7731/KIFSE.2012.26.3.008.
6. S Dembele, J. X Wen and J. F Sacadura, “Experimental Study of Water Sprays for the Attenuation of Fire Thermal Radiation”, Journal of Heat Transfer, Vol. 123, No. 3, pp. 534-543 (2001),
https://doi.org/10.1115/1.1371921.
7. L. A Dombrovsky and S Dembele, “An Improved Solution for Shielding of Thermal Radiation from Fires Using Mist Curtains of Pure Water or Seawater”, Computational Thermal Sciences, Vol. 14, No. 4, pp. 1-18 (2022),
https://doi.org/10.1615/ComputThermalScien.2022041314.
8. W. J You and H. S Ryou, “Analysis on the Relations of Droplet Size Distribution and Optical Depth in Water Curtain”, Fire Science and Engineering, Vol. 30, No. 2, pp. 62-67 (2016),
https://doi.org/10.7731/KIFSE.2016.30.2.062.
9. J. G Jo and C. Y Lee, “Experimental Study on Thermal Radiation Attenuation Using Water Mist of Twin-fluid Atomizer”, Fire Science and Engineering, Vol. 35, No. 4, pp. 24-32 (2021),
https://doi.org/10.7731/KIFSE.67a3ae31.
10. P Zhu, X Wang, Z Wang, H Cong and X Ni, “Experimental and Numerical Study on Attenuation of Thermal Radiation from Large-Scale Pool Fires by Water Mist Curtain”, Journal of Fire Sciences, Vol. 33, No. 4, pp. 269-289 (2015),
https://doi.org/10.1177/0734904115585796.
11. K McGrattan, S Hostikka, R McDermoot, J Floyd and M Vanella, “Fire Dynamics Simulator Technical Reference Guide”, NIST SP 1018-1, 6th Ed., (2019).
12. R Mehaddi, A Collin, P Boulet, Z Acem, J Telassamou, S Becker, F Demeurie and J. -Y Morel, “Use of a Water Mist for Smoke Confinement and Radiation Shielding in Case of Fire during Tunnel Construction”, International Journal of Thermal Sciences, Vol. 148, pp. 106156(2020),
https://doi.org/10.1016/j.ijthermalsci.2019.106156.
13. G. H Ko, “Numerical Study on the Attenuation Effect of Water Mist on Thermal Radiation”, Fire Science and Engineering, Vol. 34, No. 4, pp. 7-12 (2020),
https://doi.org/10.7731/KIFSE.67dab4d2.
14. J. G Jo and C. Y Lee, “Examination on Effects of Spray Characteristicis of Water Mist on Thermal Radiation Attenuation Using Fire Dynamics Simulator”, Fire Science and Engineering, Vol. 35, No. 1, pp. 1-10 (2021),
https://doi.org/10.7731/KIFSE.d59cca98.
15. K McGrattan, S Hostikka, R McDermoot, J Floyd and M Vanella, “Fire Dynamics Simulator User's Guide”, NIST SP 1019, 6th Ed., (2019).
16. J Wen, S Dembele, M Yang, V Tam and J Wang, “Numerical Investigation on the Effectiveness of Water Spray Deluge in Proviing Cooling, Smoke Dilution and Radiation Attenuation in Fires”, Fire Safety Science-Proceedings of the 9
th International Symposium, pp. 639-650 (2008),
https://doi.org/10.3801/iafss.fss.9-639.