1. G. H. Cho and I. H. Yeo, “Evaluation on Fire Spread Speed of Standard Rack in Korea for Performance based Fire Extinguishing System”, Fire Science and Engineering, Vol. 30, No. 6, pp. 84-91 (2016),
https://doi.org/10.7731/KIFSE.2016.30.6.084.
3. P. H. Thomas, “Some Comments on Fire Spread in High Racked Storage of Goods”, Department of Fire Safety Engineering and Systems Safety, Lund University, Lund, SE, (1995).
4. E. Markus, A. Snegirev, E. Kuznetsov and L. Tanklevskiy, “Fire Growth in a High-rack Storage”, Proceedings of the Ninth International Seminar on Fire and Explosion Hazards, Vol. 2, pp. 796-807 (2019),
https://doi.org/10.1∐/SPBPU/2/k19-70.
7. NFPA 13, “Standard for the Installation of Sprinkler Systems”, National Fire Protection Association, (2022).
8. KFS 630, “Standard on Fire Protection for Logistics Warehouse”, Korean Fire Protection Association, (2020).
9. K. O. Choi and D. M. Choi, “Experimental Study on the Suppression Performance of Sprinkler Systems in Rack-type Warehouses”, Fire Science and Engineering, Vol. 33, No. 3, pp. 44-50 (2019),
https://doi.org/10.7731/KIFSE.2019.33.3.044.
10. S. G. Choi, M. W. Kim and G. H. Lee, “Experimental Study on Condensation of Air Sampling Smoke Detector in Frozen Warehouse Environment”, Fire Science and Engineering, Vol. 37, No. 6, pp. 40-47 (2023),
https://doi.org/10.7731/KIFSE.9b5fe136.
11. S. B. Lee, M. S. Kim and S. H. Min, “A Study on the Comparison of Aspirating Smoke Detector and General Smoke Detection Time according to the Fire Speed and Location of Logistics Warehouse through FDS”, Journal of the Society of Disaster Information, Vol. 19, No. 3, pp. 608-623 (2023),
https://doi.org/10.15683/kosdi.2023.9.30.608.
13. W. H. Kim and Y. J. Lee, “A Field Survey of Rack-Type Warehouse for Commodity Classification System in Korea”, Fire Science and Engineering, Vol. 30, No. 2, pp. 98-105 (2016),
https://doi.org/10.7731/KIFSE.2016.30.2.098.
14. D. B. Kim and J. H. Jang, “A Study on Architectural Countermeasures of Prevention of Fire Propagation Through the Field Survey of Warehouse”, Journal of the Korean Society of Hazard Mitigation, Vol. 17, No. 1, pp. 15-21 (2017),
https://doi.org/10.9798/KOSHAM.2017.17.1.15.
17. M. W. Park, S. H. Hong, K. O. Choi, D. M. Choi and S. J. Kim, “An Experimental Study on the Application of Horizontal Barrier and In-Rack Sprinklers to Prevent Vertical Spread of Rack-type Warehouse Fires”, Journal of the Korean Society of Safety, Vol. 34, No. 5, pp. 15-21 (2019),
https://doi.org/10.14346/JKOSOS.2019.34.5.15.
18. National Institute of Standards and Technology (NIST), “Fire Dynamics Simulator Ver6.8.0”, (2023).
19. G. H. Cho and H. S. Yun, “Analytical Study on the Settings and Fire Spreading Characteristics of Representative Rack Structures in Korean Logistics Facilities”, Journal of the Korean Society of Hazard Mitigation, Vol. 24, No. 3, pp. 123-129 (2024),
https://doi.org/10.9798/KOSHAM.2023.24.3.123.
20. K. McGrattan, R. McDermott, C. Weinschernk, K. Overholt, S. Hostikka and J. Floyd, “Fire Dynamics Simulator, User's Guide”, “NIST SP 1019”, Sixth Edition., NIST, Gaithersburg, MD (2017).
21. K. B. McGrattan, J. Floyd, G. P. Forney, H. R. Baum and S. Hostikka, “Improved Radiation and Combustion Routines for a Large Eddy Simulation Fire Model”, Proceedings of the 7th International Symposium on Fire Safety Science, pp. 827-838 (2003),
https://doi.org/10.3801/IAFSS.FSS.7-827.
22. D. T. Sheppard, “Spray Characteristics of Fire Sprinklers”, Doctoral's Thesis, Dept. of Mechanical Engineering, Northwestern University, (2002).
23. S. C. Kim and J. Y. Kim, “An Experimental Study on the Droplet Size Distribution of Sprinkler Spray for Residential Building”, Journal of ILASS-Korea, Vol. 20, No. 3, pp. 175-180 (2015),
https://doi.org/10.15435/JILASSKR.2015.20.3.175..