2. Korea Industrial Health Association, Safety Management by Industry”. The Safety Technology, Vol. 122, pp. 52-55 (2008).
3. H Singh and A. K. Jain, “Ignition, Combustion, Toxicity, and Fire Retardancy of Polyurethane Foams: A Comprehensive Review”, Journal of Applied Polymer Science, Vol. 111, No. No. 2, pp. 1115-1143 (2009),
https: //doi.org/10.1002/app.29131.
5. M Paabo and B. C. Levin, “A Review of the Literature on the Gaseous Products and Toxicity Generated from the Pyrolysis and Combustion of Rigid Polyurethane Foams”, Fire and Materials, Vol. 11, No. No. 1, pp. 1-29 (1987),
https: //doi.org/10.1002/fam.810110102.
7. M Zhu, Z Ma, L Liu, J Zhang, S Huo and P Song, “Recent Advances in Fire-Retardant Rigid Polyurethane Foam”, Journal of Materials Science & Technology, Vol. 112, No. No. 10, pp. 315-328 (2022),
https: //doi.org/10.1016/j.jmst.2021.09.062.
8. A Yadav, F. M. de Souza, T Dawsey and R. K. Gupta, “Recent Advancements in Flame-Retardant Polyurethane Foams: A Review”, Industrial &Engineering Chemistry Research, Vol. 64, No. No. 41, pp. 15046-15065 (2022),
https: //doi.org/10.1021/acs.iecr.2c02670.
9. M. D. Hossain, M. K. Hassan, M Akl, S Pathirana, P Rahnamayiezekavat, G Douglas, T Bhat and S Saha, “Fire Behavior of Insulation Panels Commonly Used in High-rise Buildings”, Fire, Vol. 5, No. No. 3, pp. 81(2022),
https: //doi.org/10.3390/fire5030081.
11. S. Y. Mun, J. H. Lee and C. H. Hwang, “Measurement of Pyrolysis Properties for Fire Spread Simulations of Spray Polyurethane Foam”, Fire Science and Engineering, Vol. 36, No. No. 6, pp. 29-37 (2022),
https: //doi.org/10.7731/KIFSE.ef1b32a9.
12. “ISO 5660-1 “Rate of Heat Release of Building Products (Cone Calorimeter)”, International Standards Organization, Geneva, Switzerland (1992).
13. S Ryu, S. Y. Mun and C. H. Hwang, “Effect of the Cone Heater Scale Compliant with the ISO 5660 Standard on Spatial Uniformity of Radiant Heat Flux”, Fire Science and Engineering, Vol. 34, No. No. 5, pp. 27-33 (2020),
https: //doi.org/10.7731/KIFSE.ad1befcd.
14. S. Y. Mun, C. H. Hwang and S. C. Kim, “CO and Soot Yields of Wood Combustibles for a Kitchen Fire Simulation”, Fire Science and Engineering, Vol. 33, No. No. 1, pp. 76-84 (2019),
https: //doi.org/10.7731/KIFSE.2019.33.1.076.
15. S. Y. Mun and C. H. Hwang, “Influence of Radiant Heat Flux on Combustion Properties of Flame Retardant Cable”, Fire Science and Engineering, Vol. 33, No. No. 4, pp. 29-36 (2019),
https: //doi.org/10.7731/KIFSE.2019.33.3.029.
16. S Ryu, B Jang and D Rie, “Effect of Heat Transfer on Weighing Devices in Cone Calorimeter”, Journal of the Korean Society of Hazard Mitigation, Vol. 20, No. No. 6, pp. 115-126 (2020),
https: //doi.org/10.9798/KOSHAM.2020.20.6.115.
17. S. Y. Mun, J. H. Cho and C. H. Hwang, “Effects of External Heat Flux and Exhaust Flow Rate on CO and Soot Yields of Acrylic in a Cone Calorimeter”, Applied Sciences, Vol. 11, No. No. 13, pp. 5942(2021),
https: //doi.org/10.3390/app11135942.
18. J. H. Lee, “Experimental Studies on the Burning Characteristics According to Curing Time of Spray Polyurethane Foam”, Master's Thesis, Daejeon University, (2022).