산불 지표화의 1차원 화염전파 모델의 수치해석 연구 - 평지조건 기반에서 -
김동현, 전중효의, 통본규우, 이명보, 김광일
1국립산림과학원 산불연구과
2Disaster Prevention Research Institute Kyoto University
3Disaster Prevention Research Institute Kyoto University
4인제대학교 보건안전공학과
A Numerical Study of 1-D Surface Flame Spread Model - Based on a Flatland Conditions -
Kim Dong-Hyun, Tanaka Takeyoshi, Himoto Keisuke, Lee Myung-Bo, Kim Kwang-Il
1Department of Forestry Research, National Forestry Academy
2Disaster Prevention Research Institute Kyoto University
3Disaster Prevention Research Institute Kyoto University
4Department of Health and Safety Engineering, Inje University
요약
산불의 확산특성은 일반적으로 가연물의 특성, 지형, 바람조건과 같은 기상 상태등과 관련이 있다. 산불의 발달과정에 있어 수치해석을 통한 확산예측 모델은 열전달 과정에 기본을 둔 열에너지 전달에 대한 해석이 가장 일반적인 방법론이다. 산불의 발생시 열에너지의 전파속도를 해석하는 것은 화염의 생성과 열전달, 그리고 소멸에 이르는 전 과정에 대한 물리적, 화학적 해석을 통해 화염의 이동에 따른 전파속도로 추정할 수 있다. 본 논문에서는 고체연소물질의 표면화염전파에 대한 수치해석을 통해 1차원 지표화 확산모델식을 제시하였다. 1차원 확산모델식은 평지상태에서 풍속조건에 따른 화염의 전파속도 산정식으로써 지표연료의 화염유지시간, 화염의 높이, 화염의 온도, 지표연료의 착화온도 등에 대한 실험 및 이론식을 적용하였다. 실험값 및 다른 모델식과의 ROS 비교 결과, 풍속 3 m/s 이하의 조건에서는 지수함수식의 증가곡선을 나타내는 경향을 보였다. 침엽수종인 소나무 낙엽에 대한 수치해석값과 실험값을 비교한 결과, 풍속 1-2m/s 조건에서는 확산속도가 약 10% 상향예측이 되었고 풍속 3m/s 조건에서는 약 20% 하향예측 되었다. 따라서 앞으로 지표화 확산 예측을 위해 본 연구결과에서 얻어진 화염확산 알고리즘을 이용한 초기 산불확산 예측 적용이 가능할 것으로 사료된다.
Abstract
The characteristics of the spread of a forest fire are generally related to the attributes of combustibles, geographical features, and meteorological conditions, such as wind conditions. The most common methodology used to create a prediction model for the spread of forest fires, based on the numerical analysis of the development stages of a forest fire, is an analysis of heat energy transmission by the stage of heat transmission. When a forest fire breaks out, the analysis of the transmission velocity of heat energy is quantifiable by the spread velocity of flame movement through a physical and chemical analysis at every stage of the fire development from flame production and heat transmission to its termination. In this study, the formula used for the 1-D surface forest fire behavior prediction model, derived from a numerical analysis of the surface flame spread rate of solid combustibles, is introduced. The formula for the 1-D surface forest fire behavior prediction model is the estimated equation of the flame spread velocity, depending on the condition of wind velocity on the ground. Experimental and theoretical equations on flame duration, flame height, flame temperature, ignition temperature of surface fuels, etc., has been applied to the device of this formula. As a result of a comparison between the ROS(rate of spread) from this formula and ROSs from various equations of other models or experimental values, a trend suggesting an increasing curved line of the exponent function under 3m/s or less wind velocity condition was identified. As a result of a comparison between experimental values and numerically analyzed values for fallen pine tree leaves, the flame spread velocity reveals a prediction of an approximately 10% upward tendency under wind velocity conditions of 1 to 2m/s, and of an approximately 20% downward tendency under those of 3m/s.
Key Words: Forest fire, Surface fire, flame spread rate, Wind velocity, Rate of spread


ABOUT
BROWSE ARTICLES
EDITORIAL POLICY
AUTHOR INFORMATION
Editorial Office
Room 906, The Korea Science Technology Center The first building, 22, Teheran-ro 7 Gil, Gangnam-gu, Seoul, Republic of Korea
Tel: +82-2-555-2450/+82-2-555-2452    Fax: +82-2-3453-5855    E-mail: kifse@hanmail.net                

Copyright © 2025 by Korean Institute of Fire Science and Engineering.

Developed in M2PI

Close layer
prev next